Search Results
Search this site
13030 results found with an empty search
- AMCI-XR240-TS-0085 | AMCI MEDICAL IMAGING
AMX Troubleshooting Item < Search more Heading 6 Heading 6 Heading 6 Heading 6 Heading 6 Previous Next
- 1000904P17 | AMCI MEDICAL IMAGING
AMX Parts List 1000904P17 Flat Washer 1.266 ID 0.5 OD 0.032 Thick Fastener Retainer Multi New AMX-4 See More
- 5150092-2 | AMCI MEDICAL IMAGING
AMX Parts Item < Search more 5150092-2 USB Wireless Bar Code Reader Cable Assembly Thorax Mid Section Harvested Optima XR200amx, Optima XR220amx, Optima XR240amx Use only for XR240 systems. Can NOT be used in China - does not meet WiFi compliance Previous Next Request price quote
- AMCI-AMX4-TS-0051 | AMCI MEDICAL IMAGING
AMX Troubleshooting Item < Search more Heading 6 Heading 6 Heading 6 Heading 6 Heading 6 Previous Next
- 2123664 | AMCI MEDICAL IMAGING
AMX Parts Item < Search more 2123664 Capacitor Hardware Nylon Hex Nut 12mm Diameter Plastic Generator Mid Section New, Harvested AMX-4+, Definium AMX 700 Previous Next Request price quote
- 46-136282P63 | AMCI MEDICAL IMAGING
AMX Parts Item < Search more 46-136282P63 Bearing 0.472 ID 1.259 OD Hardware Base New, Harvested AMX-4, AMX-4+, Definium AMX 700 Previous Next Request price quote
- AMCI-XR220-TS-0048 | AMCI MEDICAL IMAGING
AMX Troubleshooting List Why will my GE Optima XR240amx detector not pair in the charging bin? The detector may be unregistered, incorrectly configured, or unable to communicate through the wireless access point. Detector not registered; AP configuration issue; unsupported wireless country/channel combination. Check the registered-detector list. Register the detector if needed, then insert it in the proper bin to pair. If AP configuration messages appear, verify the selected country configuration and AP operation. Read More Why is my GE Optima XR240amx detector not charging in the bin? The manual lists the detector battery, charging cable, docking connector, bin control board, LVLE power, and indicator circuitry as possible causes. Defective battery; damaged charging cable; stuck/faulty docking connector; BCB failure; loss of 15 VDC or 24 VDC; indicator membrane/cable fault. Confirm the detector is recognized. Inspect the battery, charging cable and spring-loaded docking connector. Verify the detector is in the correct slot. If charging is shown in the UI/logs but LEDs are dark, isolate the LED membrane/indicator cable. Qualified service personnel can continue electrical checks. Read More Why are the detector charging lights on my XR240amx bin not illuminated? A dark charging indicator does not always mean the detector is not charging; the UI and detector logs should be checked. Defective LED membrane or indicator cable; BCB fault; 15 VDC loss. Verify the detector is recognized in the UI and check the detector battery log for increasing charge. If charge is increasing but the bin LEDs remain off, inspect the LED membrane and indicator cable. If charging itself is also absent, continue BCB/power troubleshooting. Read More Why does my XR240amx detector battery lose charge while tethered? The detector power supply (DPS) may be unable to support the detector while tethered. Defective detector power supply (DPS). Tether the detector and verify communication. The manual instructs service personnel to isolate the DPS by observing whether detector communication is maintained when the detector battery is unplugged. Replace the DPS if the test confirms failure. Read More Why does my XR240amx detector battery have a short duty cycle? The battery may not be reaching a full charge or the detector may be placed in the wrong charging slot. Incomplete charging cycle; detector inserted in wrong bin; charging cables connected to wrong detector-size terminal. Allow a complete charging cycle. Confirm the 14×17 detector is in its proper bin and the 10×12 detector is in its proper bin. Verify the corresponding charging cables are connected to the correct terminals. Read More Why is image transfer slow on my GE Optima XR240amx? The manual identifies near-capacity system/detector memory, weak wireless signal, and congested wireless channels as possible causes. System or detector memory approaching capacity; weak AP signal; channel congestion/interference. Restart both the system and detector for memory-related symptoms. For wireless transfer, check detector signal bars, distance to the AP, configured channels and possible hospital Wi‑Fi overlap. Read More What should I do when the XR240amx detector wireless signal is weak? Move the detector and system closer together and verify the detector LCD shows wireless connectivity. Excessive detector-to-AP distance; low signal strength; channel interference. Check the detector LCD for Wi‑Fi bars. The manual notes basic connectivity with more than one bar and advises keeping detector-to-AP distance under about 200 ft; signal should improve as they are moved closer. Read More Why does my XR240amx detector fail to boot wirelessly? Confirm the detector is registered, paired, selected as primary, and can boot successfully on the tether connection. Detector not registered; too many detectors registered; detector not primary; detector not paired; wireless communication failure. Verify detector registration and primary status. Pair the detector in the charging bin. Attempt a tethered boot to isolate the fault to wireless communication. If tether boot succeeds but wireless fails, continue AP/wireless diagnostics and collect a system snapshot if needed. Read More Why does the XR240amx say too many detectors are registered? The troubleshooting workflow identifies a registered-detector limit and directs the user to remove unused detectors before adding another. Maximum registered-detector count reached. Open detector management, review the registered detectors, remove an unused detector if necessary, then register and pair the desired detector. Read More How do I make a detector primary on the GE Optima XR240amx? Select the desired detector as the primary detector in Detector Management; a reboot may be required for boot to complete. Wrong detector selected as primary. Open Detector Management, select the desired detector as primary, and allow the detector to complete boot. If necessary, reboot the detector after changing primary status. Read More
- 5451000-14 | AMCI MEDICAL IMAGING
AMX Parts Item < Search more 5451000-14 Firmware USB Dongle for XR220amx (Compatiable with Spyder System Controller 7350002) Application Firmware Software Thorax Mid Section New, Harvested. Refurbished Optima XR200amx, Optima XR220amx Previous Next Request price quote
- 46-136394P2 | AMCI MEDICAL IMAGING
AMX Parts List 46-136394P2 Grommet 1.31 ID 1.62 Hole 20.0 OD Fastener Retainer Generator Mid Section New AMX-4 See More
- 5761642 | AMCI MEDICAL IMAGING
AMX Parts List 5761642 LL Power ON OFF Button for FlashPad Detector Electronic Component Storage Bin Harvested, Refubished Optima XR220amx See More