Search Results
Search this site
4481 results found with an empty search
- GE 5557061 Ground Cable Caterpillar to Base | AMCI Medical…
GE 5557061 Ground Cable Caterpillar to Base for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical… GE Healthcare Part No. 5557061 Part Type Cable Assembly Section Area Thorax Mid Section Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5557061 Ground Cable Caterpillar to Base Part Description
- GE 46-303755P1 Battery (Do not Ship by Air) | AMCI Medical…
GE 46-303755P1 Battery (Do not Ship by Air) for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-303755P1 Part Type Decal Label Tag Section Area Base Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-303755P1 Battery (Do not Ship by Air) Part Description
- GE 46-140332P1 Washer 0 | AMCI Medical Imaging
GE 46-140332P1 Washer 0 for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-140332P1 Part Type Fastener Retainer Section Area Generator Mid Section Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-140332P1 Washer 0.510 ID X 0.760 OD X 0.067 Part Description
- GE 46-270736P1 Latch Spring | AMCI Medical Imaging
GE 46-270736P1 Latch Spring for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-270736P1 Part Type Metal Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-270736P1 Latch Spring Part Description
- GE 46-221263P1 Corona Shield | AMCI Medical Imaging
GE 46-221263P1 Corona Shield for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-221263P1 Part Type Metal Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-221263P1 Corona Shield Part Description
- Error 0613 | AMCI Medical Imaging
GE mobile X-ray troubleshooting for Error 0613. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0613 Error Code / System Message Error Question What does error 0613 mean on a GE Optima XR200amx or XR220amx? Short Answer Error 0613: RTL: Issue detected on X-ray hardware enable (RTL4). Possible Causes Subsystem/category: kV. Manual recovery/error class: INHIBIT. Troubleshooting Steps Run the applicable kV, Inverter, Resonant Components and Rise Time/Regulation diagnostics and follow the specific code workflow. Parts Areas to Check < Search more Previous Next For Related Models Optima XR200amx, Optima XR220amx
- GE 46-329255G2 Firmware Kit for CPU 46-264974G4 and 46-264974G6…
GE 46-329255G2 Firmware Kit for CPU 46-264974G4 and 46-264974G6 for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray… GE Healthcare Part No. 46-329255G2 Part Type Application Firmware Software Section Area Generator Mid Section Part Condition New Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-329255G2 Firmware Kit for CPU 46-264974G4 and 46-264974G6 Part Description
- GE 5395832 SuperBee Collimator Switch label | AMCI Medical…
GE 5395832 SuperBee Collimator Switch label for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx. Available from AMCI Medical Imaging for… GE Healthcare Part No. 5395832 Part Type Decal Label Tag Section Area Collimator Part Condition New Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx Part Notes Previous Next Request price quote < Search more 5395832 SuperBee Collimator Switch label Part Description
- GE 5506646 Chain Shaft | AMCI Medical Imaging
GE 5506646 Chain Shaft for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile… GE Healthcare Part No. 5506646 Part Type Metal Section Area Horizontal Arm Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5506646 Chain Shaft Part Description
- GE 5396625 Bearing Shaft | AMCI Medical Imaging
GE 5396625 Bearing Shaft for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile… GE Healthcare Part No. 5396625 Part Type Metal Section Area Collimator Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5396625 Bearing Shaft Part Description
- FPGA_NORMAL LED | AMCI Medical Imaging
GE mobile X-ray troubleshooting for FPGA_NORMAL LED. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number FPGA_NORMAL LED Error Code / System Message FPGA_NORMAL - DS6 GREEN Error Question What does the FPGA_NORMAL LED mean on the GE Definium AMX 700? Short Answer Normal FPGA configuration is active. Possible Causes Normal FPGA configuration loaded Troubleshooting Steps Use the LED state together with the system symptom. If the LED indicates an error, inhibit or temperature condition, perform the corresponding subsystem troubleshooting before replacing the board. Parts Areas to Check Beetle Interface Board < Search more Previous Next For Related Models Definium AMX 700
- GE 5719035-2 Aruba 315 AP Fixture Assembly | AMCI Medical Imaging
GE 5719035-2 Aruba 315 AP Fixture Assembly for AMX Navigate. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5719035-2 Part Type Assembly Section Area Storage Bin Part Condition Harvested, Refurbished Compatible Model AMX Navigate Part Notes Previous Next Request price quote < Search more 5719035-2 Aruba 315 AP Fixture Assembly Part Description







