- GE 2103355 Lead Data ESD Strap | AMCI Medical Imaging
GE 2103355 Lead Data ESD Strap for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 2103355 Part Type Cable Assembly Section Area Drive Handle Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 2103355 Lead Data ESD Strap Part Description
- GE 46-220181P3 Lock washer #6 Screw Size | AMCI Medical Imaging
GE 46-220181P3 Lock washer #6 Screw Size for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-220181P3 Part Type Fastener Retainer Section Area Horizontal Arm Part Condition New Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-220181P3 Lock washer #6 Screw Size Part Description
- Slow image transfer | AMCI Medical Imaging
GE mobile X-ray troubleshooting for Slow image transfer. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Slow image transfer Error Code / System Message Error Question Why is image transfer slow on my GE Optima XR240amx? Short Answer The manual identifies near-capacity system/detector memory, weak wireless signal, and congested wireless channels as possible causes. Possible Causes System or detector memory approaching capacity; weak AP signal; channel congestion/interference. Troubleshooting Steps Restart both the system and detector for memory-related symptoms. For wireless transfer, check detector signal bars, distance to the AP, configured channels and possible hospital Wi‑Fi overlap. Parts Areas to Check < Search more Previous Next For Related Models Optima XR240amx
- GE 46-270161G1 Generator Assembly | AMCI Medical Imaging
GE 46-270161G1 Generator Assembly for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-270161G1 Part Type Assembly Section Area Generator Mid Section Part Condition Harvested, Refurbished Compatible Model AMX-4 Part Notes Optional Exchange Required Previous Next Request price quote < Search more 46-270161G1 Generator Assembly Part Description
- GE 46-270344P1 Cable 24 | AMCI Medical Imaging
GE 46-270344P1 Cable 24 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-270344P1 Part Type Hardware Section Area Horizontal Arm Part Condition New, Harvested Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-270344P1 Cable 24.15 Long (With One Ball & One Thread Fitting) Part Description
- GE 46-125384P1 Cone Brass (For 0 | AMCI Medical Imaging
GE 46-125384P1 Cone Brass (For 0 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-125384P1 Part Type Metal Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-125384P1 Cone Brass (For 0.8" Diameter 3 Conductor Cable) Part Description
- GE 2186370 Foam Blocking | AMCI Medical Imaging
GE 2186370 Foam Blocking for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 2186370 Part Type Foam Gasket Insulator Sponge Section Area Base Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 2186370 Foam Blocking Part Description
- GE 46-315954P5 Label Warning Drive With Drawer Closed…
GE 46-315954P5 Label Warning Drive With Drawer Closed English/Japanese for AMX-4, AMX-4+. Available from AMCI Medical Imaging for mobile X-ray service and… GE Healthcare Part No. 46-315954P5 Part Type Decal Label Tag Section Area Storage Bin Part Condition New Compatible Model AMX-4, AMX-4+ Part Notes Previous Next Request price quote < Search more 46-315954P5 Label Warning Drive With Drawer Closed English/Japanese Part Description
- GE 46-170684P1 Threadlocker Loctite 271 0 | AMCI Medical Imaging
GE 46-170684P1 Threadlocker Loctite 271 0 for AMX-4, AMX-4+, Definium AMX 700, Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX… GE Healthcare Part No. 46-170684P1 Part Type Adhesive Grease Oil Sealant Tape Section Area Drive Handle Part Condition New Compatible Model AMX-4, AMX-4+, Definium AMX 700, Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 46-170684P1 Threadlocker Loctite 271 0.5 CC Part Description
- GE 5412745-2 Sheet Metal Display Bracket Left | AMCI Medical…
GE 5412745-2 Sheet Metal Display Bracket Left for Optima XR240amx. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5412745-2 Part Type Metal Section Area Top Cover Part Condition Harvested Compatible Model Optima XR240amx Part Notes Previous Next Request price quote < Search more 5412745-2 Sheet Metal Display Bracket Left Part Description
- GE 5396587 Handle | AMCI Medical Imaging
GE 5396587 Handle for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile X-ray… GE Healthcare Part No. 5396587 Part Type Metal Section Area Collimator Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5396587 Handle Part Description
- Error 437 | AMCI Medical Imaging
GE mobile X-ray troubleshooting for Error 437. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 437 Error Code / System Message 437 Error Question What should I check for error 437 on the AMX-4 Series? Short Answer 1) If Error 437 occurs after exposure, check HV Transformer Tank spark gaps (0.010 in.) or X-Ray Tube may be spitting. 2) If Error 437 occurs other than during or after an exposure, the X-RAY ON signal may be active, as during pickup of drive handle or while driving. 3) Check snubbers across drive relays. 4) For static problems on units prior to Oct. 1993, refer to Service Note 3411 / ESD Kit 46-329334G1; CPU Board should be 46-264974G1 or later and Filament kVp Control Board 46-264986G1 or later. Measure drive wheels to ground = 8-10K, not >25K; wheel shaft to ground = 5-10 ohms. 5) Check connection to RC filter across Power Module SCR Q3 power pack/block. 6) Check Safety Contactor operation during PREP; Safety Contactor or microswitch may be bad. 7) On older units, insulate capacitor C5 from its retaining clamp (Service Note 3265). 8) Check CPU Board. 9) Check battery leads, tap relays and other connections. 10) Check pin spread on high-voltage cables. 11) Check Battery Charger Board. 12) Check Drive Handle Assembly/Drive Handle Enable Switches for noise injected into CPU Board; XRAY and SONALERT may also activate. 13) Check for diode across K1 coil (Overall Schematic Sheet #2, Loc. 7-F; CQA 943970). 14) During CAL GENERATOR kVp calibration, make sure jumper between TP-14 and TP-15 is not open. Possible Causes 1) If error 437 occurs after exposure, check HV Transformer Tank spark gaps (0.010”) or the X-ray Tube (XRT) may be spitting. 2) If error 437 occurs other than during or after an exposure, the X-RAY ON signal may be active (as during pickup of drive handle or while driving) 3) Check snubbers across drive relays 4) Static problems (units prior to oct. 1993) order ESD kit part # 46-329334G1 (Refer to Service Note 3411) CPU Board should be 46-264974G1 or later and Filament kVp Control Board should be 46-264986G1 or Later). Measure Drive Wheels to Ground = 8 -10K but not >25K, Wheel shaft to Ground = 5 -10 Ohms 5) Poor connection to RC Filter across Power Module SCR Q3 Power Pack/Block 6) Poor Safety Contactor operation during PREP (Safety Contactor or Microswitch are bad) 7) Insulate (on older Units) Capacitor C5 from its retaining clamp (Refer to Service Note 3265) 8) Defective CPU Board 9) Poor connections(s); Battery leads, Tap relays, etc. 10) Poor pin spread on High Voltage Cables 11) Bad Battery Charger Board 12. Bad Drive Handle Assembly/Drive Handle enable switches—Injecting Noise into CPU Board (Also XRAY And SONALERT may activate) 13) No Diode across coil of K1 Safety Contactor coil (Overall Schematic Sheet #2, Loc. 7-F). CQA 943970 14) During CAL GENERATOR, kVp Cal - make sure jumper between TP-14 and TP-15 is NOT open Troubleshooting Steps 1) If error 437 occurs after exposure, check HV Transformer Tank spark gaps (0.010”) or the X-ray Tube (XRT) may be spitting. 2) If error 437 occurs other than during or after an exposure, the X-RAY ON signal may be active (as during pickup of drive handle or while driving) 3) Check snubbers across drive relays 4) Static problems (units prior to oct. 1993) order ESD kit part # 46-329334G1 (Refer to Service Note 3411) CPU Board should be 46-264974G1 or later and Filament kVp Control Board should be 46-264986G1 or Later). Measure Drive Wheels to Ground = 8 -10K but not >25K, Wheel shaft to Ground = 5 -10 Ohms 5) Poor connection to RC Filter across Power Module SCR Q3 Power Pack/Block 6) Poor Safety Contactor operation during PREP (Safety Contactor or Microswitch are bad) 7) Insulate (on older Units) Capacitor C5 from its retaining clamp (Refer to Service Note 3265) 8) Defective CPU Board 9) Poor connections(s); Battery leads, Tap relays, etc. 10) Poor pin spread on High Voltage Cables 11) Bad Battery Charger Board 12. Bad Drive Handle Assembly/Drive Handle enable switches—Injecting Noise into CPU Board (Also XRAY And SONALERT may activate) 13) No Diode across coil of K1 Safety Contactor coil (Overall Schematic Sheet #2, Loc. 7-F). CQA 943970 14) During CAL GENERATOR, kVp Cal - make sure jumper between TP-14 and TP-15 is NOT open Parts Areas to Check CPU Board; Battery Charger Board; HV Transformer Tank; X-Ray Tube; High Voltage Cable; Power Module SCR Q3; Safety Contactor; Battery; Tap Relay; Drive Handle < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700