AMX Troubleshooting & Technical Support

Results Count

Error Number

Error 102

Error Code System Message

102

AMX-4, AMX-4+, Definium AMX 700, ERROR 102
Question

What should I check for errors 102 on the AMX-4 Series?

Short Answer

1) Perform recalibration of the “CAL BATT CHARGER” portion. 2) Replace the Battery Charger Board.

Possible Causes

Perform recalibration of the “CAL BATT CHARGER” portion. 2) Replace the Battery Charger Board.

Troubleshooting Steps

1) Perform recalibration of the “CAL BATT CHARGER” portion. 2) Replace the Battery Charger Board.

Parts Areas to Check

Battery Charger Board; Battery

For Related Models

AMX-4, AMX-4+, Definium AMX 700

Error Number

Error 103

Error Code System Message

103

AMX-4, AMX-4+, Definium AMX 700, ERROR 103, Error 103
Question

What should I check for error 103 on the AMX-4 Series?

Short Answer

Safety contactor contacts may be stuck closed.

Possible Causes

Safety contactor contacts may be stuck closed.

Troubleshooting Steps

Safety contactor contacts may be stuck closed.

Parts Areas to Check

Safety Contactor

For Related Models

AMX-4, AMX-4+, Definium AMX 700

Error Number

Error 103

Error Code System Message

ERROR 103 - Charge-current feedback high during trickle charge

ERROR 103, Charge-current feedback high during trickle charge, AMX-4 ERROR 103, AMX-4+ ERROR 103, Definium AMX 700 ERROR 103, GE AMX error ERROR 103
Question

What does ERROR 103 mean on a GE AMX-Series mobile X-ray?

Short Answer

ERROR 103: Charge-current feedback high during trickle charge.

Possible Causes

Feedback exceeded expected trickle range.

Troubleshooting Steps

Check charger scale-select/feedback and actual trickle-current behavior.

Parts Areas to Check

Battery set; charger board; CPU board; voltage/current feedback wiring

For Related Models

AMX-4, AMX-4+, Definium AMX 700

Error Number

Error 104

Error Code System Message

ERROR 104 - Charge-current feedback low during trickle charge

ERROR 104, Charge-current feedback low during trickle charge, AMX-4 ERROR 104, AMX-4+ ERROR 104, Definium AMX 700 ERROR 104, GE AMX error ERROR 104
Question

What does ERROR 104 mean on a GE AMX-Series mobile X-ray?

Short Answer

ERROR 104: Charge-current feedback low during trickle charge.

Possible Causes

Feedback was below expected trickle range.

Troubleshooting Steps

Check charger scale-select/feedback and actual trickle-current behavior.

Parts Areas to Check

Battery set; charger board; CPU board; voltage/current feedback wiring

For Related Models

AMX-4, AMX-4+, Definium AMX 700

Error Number

Error 104

Error Code System Message

104

AMX-4, AMX-4+, Definium AMX 700, ERROR 104, Error 104
Question

What should I check for error 104 on the AMX-4 Series?

Short Answer

Refer to Service Note 3684.

Possible Causes

Refer to Service Note 3684.

Troubleshooting Steps

Refer to Service Note 3684.

Parts Areas to Check

​

For Related Models

AMX-4, AMX-4+, Definium AMX 700