top of page

Search Results

Search this site

4481 results found with an empty search

  • Error 0468 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 0468. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0468 Error Code / System Message Error Question What does error 0468 mean on a GE Optima XR240amx? Short Answer Error 0468: Measurement circuit failure at boot. Possible Causes Subsystem/category: Rotor. Manual recovery/error class: ABORT. Troubleshooting Steps Review related generator errors. Run Rotation and Tube Rotor Impedance diagnostics. Inspect rotor communication, tube stator/harness connections, and Power/Main Auxiliary circuitry. Parts Areas to Check < Search more Previous Next For Related Models Optima XR240amx

  • HIGH FIL LIMIT | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for HIGH FIL LIMIT. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number HIGH FIL LIMIT Error Code / System Message HIGH FIL LIMIT - High filament-current calibration limit exceeded Error Question What does HIGH FIL LIMIT mean on a GE AMX-Series mobile X-ray? Short Answer HIGH FIL LIMIT: High filament-current calibration limit exceeded. Possible Causes One or more filament-current calibration parameters exceeded the high limit. Troubleshooting Steps Verify filament current, mAs/kVp calibration and tube connections; repeat filament calibration. Parts Areas to Check CPU board; calibration data; subsystem identified by the error < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • Error 0200 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 0200. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0200 Error Code / System Message Error Question What does error 0200 mean on a GE Optima XR200amx or XR220amx? Short Answer Error 0200: Fil large: Unexpected generator firmware error. Possible Causes Subsystem/category: Filament Large. Manual recovery/error class: INHIBIT. Troubleshooting Steps Review related generator errors. Run mA Measurement and the applicable filament-driver tests; inspect tube/filament connections and use the specific error workflow before replacing parts. Parts Areas to Check < Search more Previous Next For Related Models Optima XR200amx, Optima XR220amx

  • GE 13248 Fuse Holder 3AG Quick Connect | AMCI Medical Imaging

    GE 13248 Fuse Holder 3AG Quick Connect for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 13248 Part Type Electronic Component Section Area Generator Mid Section Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 13248 Fuse Holder 3AG Quick Connect Part Description

  • GE 46-279995P1 Boot On Terminals | AMCI Medical Imaging

    GE 46-279995P1 Boot On Terminals for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-279995P1 Part Type Rubber Section Area Base Part Condition New, Harvested Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-279995P1 Boot On Terminals Part Description

  • GE 2801276 Basic Common Grid with Drop On Aluminum Grid Cap…

    GE 2801276 Basic Common Grid with Drop On Aluminum Grid Cap encasement for use in Digital Radiography (CR/DR) 14x17, 6:1 or 8:1, 178 LPI, 40-72" focal for… GE Healthcare Part No. 2801276 Part Type Special Kit by AMCI Section Area Storage Bin Part Condition New, Harvested. Refurbished Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 2801276 Basic Common Grid with Drop On Aluminum Grid Cap encasement for use in Digital Radiography (CR/DR) 14x17, 6:1 or 8:1, 178 LPI, 40-72" focal Part Description

  • GE 46-208560P29 Screw 6-32 X 0 | AMCI Medical Imaging

    GE 46-208560P29 Screw 6-32 X 0 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-208560P29 Part Type Fastener Retainer Section Area Generator Mid Section Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-208560P29 Screw 6-32 X 0.875 Long Bind HD Part Description

  • GE 46-315954P3 Label Warning Drive With Drawer Closed…

    GE 46-315954P3 Label Warning Drive With Drawer Closed English/German for AMX-4, AMX-4+. Available from AMCI Medical Imaging for mobile X-ray service and… GE Healthcare Part No. 46-315954P3 Part Type Decal Label Tag Section Area Storage Bin Part Condition New Compatible Model AMX-4, AMX-4+ Part Notes Previous Next Request price quote < Search more 46-315954P3 Label Warning Drive With Drawer Closed English/German Part Description

  • GE 46-270615P1 AMX-4 Collimator ASM, (Black Charcoal Gray…

    GE 46-270615P1 AMX-4 Collimator ASM, (Black Charcoal Gray Color)same as T3438B, Made in Japan, Micro Medical Corporation for AMX-4. Available from AMCI… GE Healthcare Part No. 46-270615P1 Part Type Assembly Section Area Collimator Part Condition Harvested, Refurbished Compatible Model AMX-4 Part Notes Optional Exchange Required Previous Next Request price quote < Search more 46-270615P1 AMX-4 Collimator ASM, (Black Charcoal Gray Color)same as T3438B, Made in Japan, Micro Medical Corporation Part Description

  • GE 46-239865P1 Label CSA Certified | AMCI Medical Imaging

    GE 46-239865P1 Label CSA Certified for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-239865P1 Part Type Decal Label Tag Section Area X-Ray Tube Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-239865P1 Label CSA Certified Part Description

  • GE 1001492P1 Bushing | AMCI Medical Imaging

    GE 1001492P1 Bushing for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 1001492P1 Part Type Fastener Retainer Section Area Multi Part Condition New Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 1001492P1 Bushing Part Description

  • Error 0486 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 0486. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0486 Error Code / System Message Error Question What does error 0486 mean on a GE Optima XR200amx or XR220amx? Short Answer Error 0486: Rotor: State mismatch between Power and Main Aux modules.. Possible Causes Subsystem/category: Rotor. Manual recovery/error class: ABORT. Troubleshooting Steps Review related generator errors. Run Rotation and Tube Rotor Impedance diagnostics; inspect tube-stator/rotor wiring and Power/Main Auxiliary communication. Parts Areas to Check < Search more Previous Next For Related Models Optima XR200amx, Optima XR220amx

bottom of page