top of page

Search Results

Search this site

4481 results found with an empty search

  • GE 46-303430P1 Battery Replacement History Label | AMCI Medical…

    GE 46-303430P1 Battery Replacement History Label for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-303430P1 Part Type Decal Label Tag Section Area Base Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-303430P1 Battery Replacement History Label Part Description

  • GE 5761534-2 LED Collimator Handle Assembly | AMCI Medical…

    GE 5761534-2 LED Collimator Handle Assembly for AMX Navigate. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5761534-2 Part Type Assembly Section Area Collimator Part Condition Harvested, Refurbished Compatible Model AMX Navigate Part Notes Previous Next Request price quote < Search more 5761534-2 LED Collimator Handle Assembly Part Description

  • GE 46-173632G2 Filter Half Value | AMCI Medical Imaging

    GE 46-173632G2 Filter Half Value for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-173632G2 Part Type Metal Section Area Collimator Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-173632G2 Filter Half Value Part Description

  • Error 466 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 466. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 466 Error Code / System Message ERROR 466 - Hardware backup timer expired Error Question What does ERROR 466 mean on a GE AMX-Series mobile X-ray? Short Answer ERROR 466: Hardware backup timer expired. Possible Causes Exposure hardware backup timing limit expired. Troubleshooting Steps Check backup timer status/oscillator and technique duration; review battery/timing conditions. Parts Areas to Check Generator control board; CPU board; inverter/rotor/filament/tap/HV subsystem indicated by the fault < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • GE 5316575 Lock Latch Updated Soleniod Plunger With Extended…

    GE 5316575 Lock Latch Updated Soleniod Plunger With Extended Leads for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service… GE Healthcare Part No. 5316575 Part Type Assembly Section Area Generator Mid Section Part Condition Harvested, Refurbished Compatible Model AMX-4+, Definium AMX 700 Part Notes Optional Exchnage Required Previous Next Request price quote < Search more 5316575 Lock Latch Updated Soleniod Plunger With Extended Leads Part Description

  • GE 46-220189P1 Receiver Stud 0 | AMCI Medical Imaging

    GE 46-220189P1 Receiver Stud 0 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-220189P1 Part Type Fastener Retainer Section Area Base Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-220189P1 Receiver Stud 0.135 Diameter Hole Part Description

  • CAL TAP ERROR 6 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for CAL TAP ERROR 6. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number CAL TAP ERROR 6 Error Code / System Message CAL TAP ERROR 6 - Filament-current feedback out of range Error Question What does CAL TAP ERROR 6 mean on a GE AMX-Series mobile X-ray? Short Answer CAL TAP ERROR 6: Filament-current feedback out of range. Possible Causes Filament-current feedback was outside the allowed calibration window. Troubleshooting Steps Check filament feedback, mAs calibration, tube/cathode connections and repeat tap calibration. Parts Areas to Check CPU board; calibration data; subsystem identified by the error < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • After stored now behaves abnormally | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for After stored now behaves abnormally. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number After stored now behaves abnormally Error Code / System Message Error Question What should I do if an XR200amx or XR220amx has been stored and now behaves abnormally? Short Answer A system stored at low temperature or with batteries connected/discharged can show low-temperature, low-charge, shutdown and generator errors without necessarily requiring parts. Possible Causes Cold system; self-discharge; very low state of charge; improper storage. Troubleshooting Steps Allow a cold system to stabilize to the specified environment. Fully recharge it using the approved charging practice, then reassess errors before replacing batteries or generator components. Parts Areas to Check < Search more Previous Next For Related Models Optima XR200amx, Optima XR220amx

  • GE 5725837-1 Access Point Label for The Rest of the World |…

    GE 5725837-1 Access Point Label for The Rest of the World for Optima XR240amx. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5725837-1 Part Type PC Computer Connectivity Network Section Area Thorax Mid Section Part Condition Harvested, Refurbished Compatible Model Optima XR240amx Part Notes Conversion Upgrade Kit Part, required part for conversion from XR220amx to XR240amx Previous Next Request price quote < Search more 5725837-1 Access Point Label for The Rest of the World Part Description

  • GE 5506700 Horizontal Arm Assembly | AMCI Medical Imaging

    GE 5506700 Horizontal Arm Assembly for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx. Available from AMCI Medical Imaging for mobile X-ray… GE Healthcare Part No. 5506700 Part Type Assembly Section Area Horizontal Arm Part Condition Harvested, Refurbished Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx Part Notes Optional Exchange Required Previous Next Request price quote < Search more 5506700 Horizontal Arm Assembly Part Description

  • GE 7350002 Spyder System Controller | AMCI Medical Imaging

    GE 7350002 Spyder System Controller for Optima XR220amx, Optima XR240amx. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 7350002 Part Type Circuit Board Section Area Thorax Mid Section Part Condition Harvested, Refurbished Compatible Model Optima XR220amx, Optima XR240amx Part Notes Previous Next Request price quote < Search more 7350002 Spyder System Controller Part Description

  • GE 5396590 Angle Plate 4 | AMCI Medical Imaging

    GE 5396590 Angle Plate 4 for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile… GE Healthcare Part No. 5396590 Part Type Metal Section Area Collimator Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5396590 Angle Plate 4 Part Description