top of page

Search Results

Search this site

4481 results found with an empty search

  • GE 46-250207P25 Frame for Cross Plate | AMCI Medical Imaging

    GE 46-250207P25 Frame for Cross Plate for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-250207P25 Part Type Metal Section Area Collimator Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-250207P25 Frame for Cross Plate Part Description

  • Error 0467 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 0467. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0467 Error Code / System Message Error Question What does error 0467 mean on a GE Optima XR240amx? Short Answer Error 0467: Current measurement issue on rotation. Possible Causes Subsystem/category: Rotor. Manual recovery/error class: ABORT. Troubleshooting Steps Review related generator errors. Run Rotation and Tube Rotor Impedance diagnostics. Inspect rotor communication, tube stator/harness connections, and Power/Main Auxiliary circuitry. Parts Areas to Check < Search more Previous Next For Related Models Optima XR240amx

  • GE 46-136282P93 Bearing ID 0 | AMCI Medical Imaging

    GE 46-136282P93 Bearing ID 0 for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-136282P93 Part Type Hardware Section Area Horizontal Arm Part Condition New, Harvested Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-136282P93 Bearing ID 0.3125 x OD 0.6882 x Width 0.2500" Part Description

  • GE 46-184877P2 Relay SPDT 110 VDC 25A (K1 K2 K3) | AMCI Medical…

    GE 46-184877P2 Relay SPDT 110 VDC 25A (K1 K2 K3) for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and… GE Healthcare Part No. 46-184877P2 Part Type Electronic Component Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-184877P2 Relay SPDT 110 VDC 25A (K1 K2 K3) Part Description

  • GE 5414030 Gimp Seal Right Hand | AMCI Medical Imaging

    GE 5414030 Gimp Seal Right Hand for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx. Available from AMCI Medical Imaging for mobile X-ray… GE Healthcare Part No. 5414030 Part Type Rubber Section Area Thorax Mid Section Part Condition New Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx Part Notes Previous Next Request price quote < Search more 5414030 Gimp Seal Right Hand Part Description

  • Error 43B | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 43B. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 43B Error Code / System Message 43B Error Question What should I check for error 43b on the AMX-4 Series? Short Answer 1) Check CPU Board. 2) Check cables from CPU Board to 1 kHz Inverter Driver Board and CPU Board to Filament kVp Board. 3) Check HV cable(s). 4) Check HV Transformer Tank; a bad tank may also trip the breaker. 5) Check for bad or old-style 1 kHz Inverter Driver Board; replace with newer style orderable part #46-288764G1 or later, which has more noise immunity. 6) Replace/check Filament kVp Board. 7) Check tap relay contact(s). 8) Check X-Ray Control Module Assembly. Possible Causes 1) Defective CPU Board 2) Bad cables from CPU Board to 1 KHz Inverter Board and CPU Board to Filament kVp Board 3) HV Cable(s) bad 4) HV Transformer Tank bad (Also breaker trips) 5) Bad or Old Style 1 KHz Inverter Board - replace with newer style orderable part # 46-288764G1 Board or later (has more noise immunity) 6) Replace Filament kVp Board 7) Check tap relay(s)’s contacts, clean with 90% alcohol fast evaporating solvent if there is oxidation 8) X-Ray Control Module Assembly is bad Troubleshooting Steps 1) Defective CPU Board 2) Bad cables from CPU Board to 1 KHz Inverter Board and CPU Board to Filament kVp Board 3) HV Cable(s) bad 4) HV Transformer Tank bad (Also breaker trips) 5) Bad or Old Style 1 KHz Inverter Board - replace with newer style orderable part # 46-288764G1 Board or later (has more noise immunity) 6) Replace Filament kVp Board 7) Check tap relay(s)’s contacts, clean with 90% alcohol fast evaporating solvent if there is oxidation 8) X-Ray Control Module Assembly is bad Parts Areas to Check CPU Board; Filament kVp Board; 1 kHz Inverter Board; HV Transformer Tank; Tap Relay < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • GE 2273440-1 Vertical Column Assembly 76 inch | AMCI Medical…

    GE 2273440-1 Vertical Column Assembly 76 inch for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 2273440-1 Part Type Assembly Section Area Vertical Column Part Condition Harvested, Refurbished Compatible Model AMX-4+, Definium AMX 700 Part Notes Optional Exchnage Required Previous Next Request price quote < Search more 2273440-1 Vertical Column Assembly 76 inch Part Description

  • GE 2237775 Back Tube Cover Old Type 4 Holes for RADPLUS 2100…

    GE 2237775 Back Tube Cover Old Type 4 Holes for RADPLUS 2100 (Configuration 1) for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile… GE Healthcare Part No. 2237775 Part Type Plastic Section Area X-Ray Tube Part Condition New, Harvested Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 2237775 Back Tube Cover Old Type 4 Holes for RADPLUS 2100 (Configuration 1) Part Description

  • GE 5731854 Detector Floating Bracket Assembly | AMCI Medical…

    GE 5731854 Detector Floating Bracket Assembly for Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5731854 Part Type Assembly Section Area Storage Bin Part Condition Harvested, Refurbished Compatible Model Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5731854 Detector Floating Bracket Assembly Part Description

  • GE 5797607-7 Generation 2 only Optima XR240amx Gen 2 Critical…

    GE 5797607-7 Generation 2 only Optima XR240amx Gen 2 Critical Care Suite Software Collector (required for upgrade & conversion part) for Optima XR200amx,… GE Healthcare Part No. 5797607-7 Part Type Application Firmware Software Section Area Thorax Mid Section Part Condition New, Harvested. Refurbished Compatible Model Optima XR200amx, Optima XR220amx, Optima XR240amx Part Notes Previous Next Request price quote < Search more 5797607-7 Generation 2 only Optima XR240amx Gen 2 Critical Care Suite Software Collector (required for upgrade & conversion part) Part Description

  • GE 5396613 Cable Assembly Collimator System Cable | AMCI…

    GE 5396613 Cable Assembly Collimator System Cable for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI… GE Healthcare Part No. 5396613 Part Type Cable Assembly Section Area Collimator Part Condition New Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5396613 Cable Assembly Collimator System Cable Part Description

  • GE 46-170392P4 Clamp Wraparound Mounting Bracket | AMCI Medical…

    GE 46-170392P4 Clamp Wraparound Mounting Bracket for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-170392P4 Part Type Fastener Retainer Section Area Generator Mid Section Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-170392P4 Clamp Wraparound Mounting Bracket Part Description