- GE 46-208908P44 Machined Screw 10-32 X 0 | AMCI Medical Imaging
GE 46-208908P44 Machined Screw 10-32 X 0 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-208908P44 Part Type Fastener Retainer Section Area X-Ray Tube Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-208908P44 Machined Screw 10-32 X 0.375 Long Flat HD Part Description
- GE 46-250207P41 L&R handle covers M3 | AMCI Medical Imaging
GE 46-250207P41 L&R handle covers M3 for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-250207P41 Part Type Fastener Retainer Common Section Area Collimator Part Condition New Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-250207P41 L&R handle covers M3.0x 0.5x 22mm Philip Flat Head - Black Color, Screw Part Description
- GE 46-279296P1 Key Switch 6 position with one key | AMCI…
GE 46-279296P1 Key Switch 6 position with one key for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-279296P1 Part Type Accessories Kit Optional Section Area Top Cover Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-279296P1 Key Switch 6 position with one key Part Description
- GE 46-279104P1 Spring Latch Top Cover | AMCI Medical Imaging
GE 46-279104P1 Spring Latch Top Cover for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-279104P1 Part Type Hardware Section Area Top Cover Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-279104P1 Spring Latch Top Cover Part Description
- Cannot calibrate kVp (gets hung), filament taps or filament current table (low filament error) etc., or load data in data base access properly, can’t enter calibration mode or getting false error codes displayed, after c | AMCI Medical Imaging
GE mobile X-ray troubleshooting for Cannot calibrate kVp (gets hung), filament taps or filament current table (low filament error) etc., or load data in data base access properly, can’t enter calibration mode or getting false error codes displayed, after c. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Cannot calibrate kVp (gets hung), filament taps or filament current table (low filament error) etc., or load data in data base access properly, can’t enter calibration mode or getting false error codes displayed, after c Error Code / System Message Error Question How do I troubleshoot this AMX-4 Series issue: Cannot calibrate kVp (gets hung), filament taps or filament current table (low filament error) etc., or load data in data base access properly, can’t enter calibration mode or getting false error codes displayed, after c? Short Answer Remove the two NOVRAM chips (U54 & U107) on the newer CPU Board and replace them with the two NOVRAM chips from the older CPU Board, if it is the same style of board. If the board is the “older” style of CPU Board that has only one NOVRAM chip, Then re-order a new CPU Board (Orderable Part # 46-264974G5 or 46-264974G6), or replace the NOVRAM chip(s) (Orderable Part # 46-230318P1) Possible Causes Problem: Cannot calibrate kVp (gets hung), filament taps or filament current table (low filament error) etc., or load data in data base access properly, can’t enter calibration mode or getting false error codes displayed, after changing out the CPU Board (part # T3497H, 46-264974G2 or later) Troubleshooting Steps Remove the two NOVRAM chips (U54 & U107) on the newer CPU Board and replace them with the two NOVRAM chips from the older CPU Board, if it is the same style of board. If the board is the “older” style of CPU Board that has only one NOVRAM chip, Then re-order a new CPU Board (Orderable Part # 46-264974G5 or 46-264974G6), or replace the NOVRAM chip(s) (Orderable Part # 46-230318P1) Parts Areas to Check CPU Board < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700
- GE 2281109-2 Gammex DAP (Dose Area Product) Meter | AMCI…
GE 2281109-2 Gammex DAP (Dose Area Product) Meter for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and… GE Healthcare Part No. 2281109-2 Part Type Accessories Kit Optional Section Area Collimator Part Condition Harvested, Refurbished Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 2281109-2 Gammex DAP (Dose Area Product) Meter Part Description
- GE 5845273 Mobile 2 | AMCI Medical Imaging
GE 5845273 Mobile 2 for AMX Navigate. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 5845273 Part Type Metal Section Area Thorax Mid Section Part Condition Harvested Compatible Model AMX Navigate Part Notes Previous Next Request price quote < Search more 5845273 Mobile 2.0 PC Side Fan Part Description
- GE 1000-M10C020-19 Hexagon Socket Head Cap Screw M10-1 | AMCI…
GE 1000-M10C020-19 Hexagon Socket Head Cap Screw M10-1 for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx. Available from AMCI Medical… GE Healthcare Part No. 1000-M10C020-19 Part Type Fastener Retainer Section Area Vertical Column Part Condition New Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx Part Notes Previous Next Request price quote < Search more 1000-M10C020-19 Hexagon Socket Head Cap Screw M10-1.5 X 20mm Long Grade 12.9 Steel Black Oxide Part Description
- GE FMI10875 FMI 10875 Cord Plug Inspection Kit related 5510875…
GE FMI10875 FMI 10875 Cord Plug Inspection Kit related 5510875 for Optima XR200amx, Optima XR220amx. Available from AMCI Medical Imaging for mobile X-ray… GE Healthcare Part No. FMI10875 Part Type Cable Assembly Section Area Thorax Mid Section Part Condition New, Harvested. Refurbished Compatible Model Optima XR200amx, Optima XR220amx Part Notes Previous Next Request price quote < Search more FMI10875 FMI 10875 Cord Plug Inspection Kit related 5510875 Part Description
- GE 46-208697P25 Bushing 1140 SR-5M-3 Black | AMCI Medical Imaging
GE 46-208697P25 Bushing 1140 SR-5M-3 Black for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-208697P25 Part Type Fastener Retainer Section Area Vertical Column Part Condition New Compatible Model AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-208697P25 Bushing 1140 SR-5M-3 Black Part Description
- Error 0x0462 | AMCI Medical Imaging
GE mobile X-ray troubleshooting for Error 0x0462. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0x0462 Error Code / System Message Error Question What does 0x0462 mean on a GE Brivo XR285amx? Short Answer 0x0462: Acceleration while in error. Possible Causes The Djinn Beetle generator reported a Rotor FW fault: Acceleration while in error. Troubleshooting Steps Run Rotation Test and Tube Rotor Impedance. Check rotor communication, tube rotation cable, stator resistance/isolation, Auxiliary LEDs/Neons, 48 V supply, and the error-data value for 0x0480 when applicable. Parts Areas to Check < Search more Previous Next For Related Models Brivo XR285amx
- GE 46-286549P2 Fuse Holder For 5mm X 20mm Fuse | AMCI Medical…
GE 46-286549P2 Fuse Holder For 5mm X 20mm Fuse for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and… GE Healthcare Part No. 46-286549P2 Part Type Electronic Component Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-286549P2 Fuse Holder For 5mm X 20mm Fuse Part Description