AMX Troubleshooting & Technical Support
Results Count
Error Number
Detector LED status BIST in progress pattern
Error Code System Message
BIST in progress pattern
Question
What does BIST in progress pattern mean on the Definium AMX 700 detector?
Short Answer
Built In Self Test running.
Possible Causes
Built In Self Test running
Troubleshooting Steps
Wait for BIST to complete before interpreting detector status.
Parts Areas to Check
TRAD digital detector
For Related Models
Definium AMX 700
Error Number
X-RAY ON LED
Error Code System Message
X-RAY ON - DS13 RED
Question
What does the X-RAY ON LED mean on the GE Definium AMX 700?
Short Answer
The X-ray ON signal is active.
Possible Causes
X-ray ON signal active
Troubleshooting Steps
Use the LED state together with the system symptom. If the LED indicates an error, inhibit or temperature condition, perform the corresponding subsystem troubleshooting before replacing the board.
Parts Areas to Check
Beetle Interface Board
For Related Models
Definium AMX 700
Error Number
12 V debug-header value low or zero
Error Code System Message
12V debug header
Question
What does low or zero 12 V on the Definium AMX 700 debug header indicate?
Short Answer
Very low 12 V suggests a current overload; 0 V can result from converter over-temperature, input over/under-voltage, converter failure or other supply faults.
Possible Causes
12 V output overload; converter over-temperature; input voltage fault; converter failure.
Troubleshooting Steps
Measure debug-header connection 2. If very low, isolate 12 V loads. If 0 V, check converter temperature/input conditions and the 12 V converter.
Parts Areas to Check
Digital Power Supply; 12 V loads
For Related Models
Definium AMX 700
Error Number
1V5 - 1.5 V FPGA core power present
Error Code System Message
1V5 - 1.5 V FPGA core power present
Question
What does “1V5” mean on a GE Definium AMX 700?
Short Answer
1V5: 1.5 V FPGA core power present.
Possible Causes
Subsystem/category: Beetle Board. Source classification: LED STATUS.
Troubleshooting Steps
Interpret the LED together with the system symptom and use the matching Beetle/power/exposure troubleshooting path.
Parts Areas to Check
Beetle Interface Board
For Related Models
Definium AMX 700
Error Number
1V5 LED
Error Code System Message
1V5 - DS19 GREEN
Question
What does the 1V5 LED mean on the GE Definium AMX 700?
Short Answer
The FPGA core voltage is present.
Possible Causes
1.5 V FPGA core power present
Troubleshooting Steps
Use the LED state together with the system symptom. If the LED indicates an error, inhibit or temperature condition, perform the corresponding subsystem troubleshooting before replacing the board.
Parts Areas to Check
Beetle Interface Board