top of page

Search Results

Search this site

4481 results found with an empty search

  • GE 5503010 HV Cable Cathode | AMCI Medical Imaging

    GE 5503010 HV Cable Cathode for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for… GE Healthcare Part No. 5503010 Part Type Cable Assembly Section Area Thorax Mid Section Part Condition Harvested Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 5503010 HV Cable Cathode Part Description

  • Error 44 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 44. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 44 Error Code / System Message ERROR 44 - Battery voltage high during prep Error Question What does ERROR 44 mean on a GE AMX-Series mobile X-ray? Short Answer ERROR 44: Battery voltage high during prep. Possible Causes Battery voltage was higher than expected during prep. Troubleshooting Steps If just charged, remove surface charge by driving briefly; otherwise verify battery voltage/calibration. Parts Areas to Check Battery set; charger board; CPU board; voltage/current feedback wiring < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • GE 46-316308G1 Lock Latch Assembly | AMCI Medical Imaging

    GE 46-316308G1 Lock Latch Assembly for AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-316308G1 Part Type Assembly Section Area Generator Mid Section Part Condition Harvested, Refurbished Compatible Model AMX-4+, Definium AMX 700 Part Notes Optional Exchnage Required Previous Next Request price quote < Search more 46-316308G1 Lock Latch Assembly Part Description

  • GE 2193201-50 Screw M4 X 8 by 6 A4-70 | AMCI Medical Imaging

    GE 2193201-50 Screw M4 X 8 by 6 A4-70 for Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging… GE Healthcare Part No. 2193201-50 Part Type Fastener Retainer Section Area Thorax Mid Section Part Condition New Compatible Model Brivo XR285amx, Optima XR200amx, Optima XR220amx, Optima XR240amx, AMX Navigate Part Notes Previous Next Request price quote < Search more 2193201-50 Screw M4 X 8 by 6 A4-70 Part Description

  • GE 46-270944G2 Switch Assembly | AMCI Medical Imaging

    GE 46-270944G2 Switch Assembly for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-270944G2 Part Type Assembly Section Area Top Cover Part Condition Harvested, Refurbished Compatible Model AMX-4 Part Notes Optional Exchange Required Previous Next Request price quote < Search more 46-270944G2 Switch Assembly Part Description

  • GE FMI10882 FMI10882 Optima XR220amx Optima XR200amx with…

    GE FMI10882 FMI10882 Optima XR220amx Optima XR200amx with Digital Upgrade Optima XR200amx Brivo XR285amx: LVLE2 Power Supply Update, LVLE Power Supply Brivo… GE Healthcare Part No. FMI10882 Part Type FMI Section Area Thorax Mid Section Part Condition New, Harvested. Refurbished Compatible Model Optima XR200amx, Optima XR220amx Part Notes Previous Next Request price quote < Search more FMI10882 FMI10882 Optima XR220amx Optima XR200amx with Digital Upgrade Optima XR200amx Brivo XR285amx: LVLE2 Power Supply Update, LVLE Power Supply Brivo xr285amx, Optima XR200amx XR220amx Related to 5510882 Part Description

  • There is a potential for ghosting to be seen on the Display Controller Board Part # 2409241 when used with the Display Board Part # 2345236 version. Ghosting results in partial illumination of some of the characters on t | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for There is a potential for ghosting to be seen on the Display Controller Board Part # 2409241 when used with the Display Board Part # 2345236 version. Ghosting results in partial illumination of some of the characters on t. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number There is a potential for ghosting to be seen on the Display Controller Board Part # 2409241 when used with the Display Board Part # 2345236 version. Ghosting results in partial illumination of some of the characters on t Error Code / System Message Error Question How do I troubleshoot this AMX-4 Series issue: There is a potential for ghosting to be seen on the Display Controller Board Part # 2409241 when used with the Display Board Part # 2345236 version. Ghosting results in partial illumination of some of the characters on t? Short Answer To prevent ghosting, remove Display Board Part #2345236 if the combination of Part #2345236 and Display Controller Board Part #2409241 is found. Replace the Display Board with Part #2345236-1. Whenever a replacement for the 46-264982G1 version of the Display Control Board is ordered, kit Part #5119876 contains a new version of both the Display Board (Part #2345236-2) and the Display Control Board (Part #2409241). Possible Causes Problem: There is a potential for ghosting to be seen on the Display Controller Board Part # 2409241 when used with the Display Board Part # 2345236 version. Ghosting results in partial illumination of some of the characters on the extreme left or extreme right of the display. While AMX4/AMX4+ systems exhibiting ghosting have not been shipped in forward production, this problem could occur in AMX4/AMX4+ systems if a service replacement part results in a non-desirable configuration of circuit boards. Applied to all AMX-4 and AMX-4+ models builds though October 2004. Troubleshooting Steps To prevent this problem from occurring, remove Display Board Part # 2345236 from unit if a combination of Part # 2345236 and Part # 2409241 is found. Replace Display Board with Part # 2345236-1. Whenever a replacement for the 46-264982G1 version of the Display Control Board is ordered, a kit (Part #5119876) containing a new version of both the Display Board (Part # 2345236-2) and the Display Control Board (Part # 2409241) will be sent. Parts Areas to Check Display Controller Board; Display Board < Search more Previous Next For Related Models AMX-4, AMX-4+, Definium AMX 700

  • GE 46-208759P4 Strap 0 | AMCI Medical Imaging

    GE 46-208759P4 Strap 0 for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-208759P4 Part Type Fastener Retainer Section Area Vertical Column Part Condition New Compatible Model AMX-4 Part Notes Previous Next Request price quote < Search more 46-208759P4 Strap 0.18 To 30.50 Bundle Wire Tie Part Description

  • GE 46-267217P21 Fuse 3 | AMCI Medical Imaging

    GE 46-267217P21 Fuse 3 for AMX-4, AMX-4+, Definium AMX 700. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. 46-267217P21 Part Type Electronic Component Section Area Generator Mid Section Part Condition New, Harvested Compatible Model AMX-4, AMX-4+, Definium AMX 700 Part Notes Previous Next Request price quote < Search more 46-267217P21 Fuse 3.15A 250V 5mm X 20mm Part Description

  • GE AID61051 Circuit Board Extender Board | AMCI Medical Imaging

    GE AID61051 Circuit Board Extender Board for AMX-4. Available from AMCI Medical Imaging for mobile X-ray service and replacement. GE Healthcare Part No. AID61051 Part Type Circuit Board Section Area Top Cover Part Condition Harvested, Refurbished Compatible Model AMX-4 Part Notes Optional Exchange Required Previous Next Request price quote < Search more AID61051 Circuit Board Extender Board Part Description

  • Error 0x0787 | AMCI Medical Imaging

    GE mobile X-ray troubleshooting for Error 0x0787. Review possible causes, diagnostic steps and service guidance from AMCI Medical Imaging. Troubleshooting AMX Error Number Error 0x0787 Error Code / System Message Error Question What does 0x0787 mean on a GE Brivo XR285amx? Short Answer 0x0787: Single Wire communication impossible. Possible Causes The Djinn Beetle generator reported a Thermal SW fault: Single Wire communication impossible. Troubleshooting Steps Run Power Supply Thermal and the applicable thermal sensor tests. Check cooling, fans, sensor wiring, tube thermal-switch resistance, and single-wire communication before replacing a module. Parts Areas to Check < Search more Previous Next For Related Models Brivo XR285amx

  • GE 5781417-4 FlashPad HD 3543, 14 x 17" (35cm x 43cm) Detector,…

    GE 5781417-4 FlashPad HD 3543, 14 x 17" (35cm x 43cm) Detector, GE Label for Optima XR240amx, AMX Navigate. Available from AMCI Medical Imaging for mobile… GE Healthcare Part No. 5781417-4 Part Type Storage Bin Section Area Storage Bin Part Condition Harvested. Refurbished Compatible Model Optima XR240amx, AMX Navigate Part Notes Required Exchange Optional Previous Next Request price quote < Search more 5781417-4 FlashPad HD 3543, 14 x 17" (35cm x 43cm) Detector, GE Label Part Description

bottom of page